Schüco Façade FW 50+

Fully tried-and-tested with endless possibilities: Schüco FW 50+ / FW 60+ – the façade system

The Schüco Façade FW 50+ allow façades and skylights of very varied design to be constructed efficiently and reliably. Their compatibility with many other Schüco systems make Schüco FW 50+ two of the best-selling façade systems in Europe.

  • From passive house-certified SI façades with maximum thermal insulation through to standard thermal insulation, the FW 50+ systems offer the right solution for every scenario and all climate regions
  • Geometrically complex skylight constructions can be easily constructed
  • A wide range of cover caps offer outstanding design options for a variety of façade styles
  • Bullet resistance, burglar resistance and blast resistance options
  • Can also be used as a fire-resistant façade (BF)
  • Electric cables are concealed within the façade system, but can be accessed for inspection
System / MaterialAluminum
EnergyThermally insulated
Façade type
Transom-mullion
Uf value (>=)
1.5
Max. glass thickness64 mm
Min. face width50 mm
Poids maximum700 kg
Structural analysis
7160,6 cm4
Approvals
Burglar resistance
RC3
Wind load resistancePN1200-PE1800
Air permeabilityA4
WatertightnessRE1200
Impact resistanceI5 / E5
Safety barrier loadingFully suitable for safety barrier loading
Surface finishesTopAlu / Decorative foils
Wind load resistancePermitted load (<=) 2.0 kN/m²; increased 3.0k N/m²

PREVIEW SPECIFICATION

Schüco FW 50+.HI, highly thermally insulated aluminium add-on construction on a timber load-bearing structure
(with brackets)
As a mullion/transom construction for multi-storey façades with a 50 mm external face width.

Design features:
The construction must have HI isolators (isolator with foam profile) to suit the infill thicknesses. The aluminium pressure plates also have additional thermal insulation tape.

Load-bearing structure:
Selection
The load-bearing structure of the façade construction must be fabricated from suitable types of wood.
Or
The load-bearing structure of the façade construction is to be fabricated from suitable types of wood supplied by the customer.
End
Wood quality, design and surface treatment are described separately. The necessary cross sections must be calculated according to DIN 1052. Furthermore, DIN EN 942 (Wood in joinery work), DIN 1055 (Anticipated loads for buildings) and “Technical regulations for the use of glazing with linear supports, DIBt, September 1998 edition” must be taken into account in the design of the construction. The load-bearing wood construction is on the inside. The space between the load-bearing structure and the add-on construction must be closed off using a gasket.
The glazing system is formed by mullion and transom profiles with C-shaped locating grooves for attachment to the load-bearing structure, as well as aluminium cover caps and/or pressure plates. The gasket locating groove of the transoms overlaps the gasket locating groove of the mullions. The overlap area must be sealed with appropriate seals. The glazing system is attached to the load-bearing structure by means of stainless steel fixing brackets. The maximum fixing intervals must be calculated in accordance with the system manufacturer’s size tables.

Glazing / insert units:
All glazing, even in the insert units, lies in the same plane. The glazing gaskets made from weather-resistant, black EPDM on the room side are of different depths in the mullions and transoms (6 mm offset).
Two individual gaskets made from weather-resistant, black EPDM, with a height of 5 mm, are positioned on the outside. Moulded gasket intersections made from EPDM must be used where mullions and transoms join.
In principle two individual gaskets and butyl tape must be used for roof glazing.

Ventilation:
Rebate base ventilation and vapour pressure equalisation are achieved at all four corners of each module field into the mullion rebate.
For field drainage and ventilation, appropriate openings must be made in the aluminium pressure plates, cover caps and gaskets.

Profile face widths:
Mullion, transom, cover caps 50 mm

Profile basic depths:
Add-on mullion 22 mm
Add-on transom 28 mm
Cover cap (mullion) 20 mm
Cover cap (transom) 15 mm

DOWNLOAD

FW 50+ mullion with aluminium
pressure plate

Drawing dxf
(dxf/ 208 KB)

Drawing dwg
(dwg/ 80 KB)

FW 50+ transom with
aluminium pressure plate

Drawing dxf
(dxf/ 168 KB)

Drawing dwg
(dwg/ 69 KB)

Transom level 2 notched into
mullion level 3

Drawing dxf
(dxf/ 199 KB)

Drawing dwg
(dwg/ 76 KB)